Home > Candidates > Roberto Tirona Aligue
Roberto Tirona Aligue

Olongapo city, Zambales, Philippines

Phone: xxx-xxx-xxxx

Email: xxx@xxxx.xxx



  • Looking For: Hvac Supervisor, Hvac Foreman

  • Occupation: Architecture and Engineering

  • Degree: High School Or Below

  • Career Level: Experienced

  • Languages: English

Career Information:

Sign up to view Roberto Tirona Aligue's full profile.

Highlights:

Skills:HVAC TEAM LEADEAR, HVAC SUPERVISOR, HVAC FOREMAN


Experiences:

HVAC SPECIALIST 12/2024 - 01/2025
Alhamda AlHamra International Company Oil and Gas/Dietsmann, Tripoli, Hay Alan Dalus Tripoli Libya Libya
Industry: OIL and Gas
Character Reference Name: AbdulGhani khadar Occupation: Supervisor HVAC Specialist Company Address: Hay Alan Dalus Tripoli Libya. (North Africa) Western Sea Sabratha PLATFOARM Telephone No. 0921304444
Preparing Work Permits / Cold Working Permits /Confine Space Entry Certificate / Hot Work Permits-Open Flame/Work Order Details Tool Box Talk / Task Risk Assesment Worksheet / Drawing Specification Work Location / Excavation Working Permits /Well Hand Over Certificate / Gas Test Certificate. Monitored New Centralized Chilled Water. Water Cooled Type Horizontal. Mc Quays WHS newest stargate Single Screw Compressor lower Noise Higher flexibility. Infinitely variable Capacity Control Unmatched Serviceability. General Characteristic Structure. Ecological HFC 134 Refrigerant Screw Compressor Deck Level and Living Quarter. Preventative Maintenance and Corrective Measure of Equipment. AHU/ Split Unit Gas Type / Wall Mounted Unit Chilled Water type/ Heating Coils/ Pumps /Ultra Violet/ Change Oil/ Fan Coils.--
General Technician 11/2021 - 11/2024
The St Regis Dubai The Palm Residences., Dubai, Dubayy [Dubai] United Arab Emirates
Industry: HOSPITALITY
Character Reference Name: Sabry Balboul Occupation: Director Company Address: The Palm Jumeirah P.O. Box 53809 Dubai United Arab Emirates Telephone No. +97142180000 Fax: +97142180001
Pre Opening and Handover by Contractor. Monitoring Equipment Plant Room Boiler Pump Room and Corridors Restaurant Swimming Pool Area Restaurant Kitchen Area. Ass Supervisor and Ass manager facing different issue in technical and other complaint regarding rooms in public area civil works painting external and internal. PPM Equipment / FHU / FCU / MHU/ ECU / Electrical Plumbing works Set Schedule Maintenance lift PPM and other Generators etc. Residences Building link task completed/transcendent. Equipment Evaluation Process. Handling Duty Mobile. Attend Engineering Works Guest Complaint.--
HVAC Foreman 11/2017 - 01/2021
Shelter Qatar W.L.L Character, Doha, Salwa Road Qatar
Industry: Maintenance and Construction
Reference Name: Claire Faustino Occupation: HR Officer Status of Employment: 3 Years 2 months Full Time Company Address: Salwa Road-Shelter Building P.O. Box: 24143 Doha-Qatar Telephone No. +974 44699677 Fax: +974445581236
Operation Facilities Preventative Maintenance and Construction. Coordinating and overseeing the daily operations of the maintenance functions. To ensure that the property and assets are maintained in the highest order through the implementation of the Quick Registration Maintenance System and the appointment of suitable competent personnel. Assists Supervises and directs the daily activities of all Maintenance Department Supervisors and subordinates. Observes activities to ensure adherence to policies and operating procedures. Check on completed repair and maintenance works to ensure that established standards have been met. Assists in the implementation, co-ordination and monitoring of the Quick Registration Maintenance Management System. Familiar with and comply with all relevant Maintenance Department policies, Processes and procedures. Perform other duties that management may from time to time reasonably required. Prepare daily and monthly Checklist of HVAC Unit. Maintain proper documents for the all activities in testing area. *Construction* Supervises junior HVAC technicians in the installation, inspection, maintenance and trouble-shooting of industrial HVAC equipment such as chillers, light commercial units to include, package, DX and split units and residential units to include split, mini-split and window units VRV/ VRF Units Verifies actual hours worked by personnel to reduce manpower expenditure and assign to other works together with other colleague. Supervise Junior HVAC technicians Refrigeration lay out and piping distribution of liquid line and gas line (low Pressure and High Pressure) Silver Brazing cupper. Supervise Junior HVAC technician for installation of Mechanical Liquid line and Gas line connected to FCU Samsung Unit Flaring nut and Silver Bracing Supervise Junior HVAC technician for Leak testing procedure with nitrogen stand by pressure 600 psi low side and high side of pipe line. Supervise Pipe fitters to lay out and install piping of FCU CHWS/CHWR, purging and flushing Chws/Chwr.--
Contractor 05/2017 - 10/2017
Self Employed, Bangkapi, Ramkhamhaeng Road Qatar
Industry: Construction HVAC Installation
Ounjit Occupation: Building Manager Site location Address: 19/18 Asakan Place Building 9 Soi Ramkhamhaeng Road, Kwang Hua Mark het Bangkapi, Bangkok 10240. Thailand. Telephone No. 0836874933
HVAC Installation and Commissioning Turn Over Installation of HVAC Unit in Condo and Apartment Unit. Computing material cost and labor cost for installation of VRV/VRF type Unit Refrigerant R410A. Purchase Cupper pipe 50 mm 1/2’ 1/4 - 3/4 ‘5/8 Electrical wire Drainage pipe/ Insulation foam / Expansion volt / fix volt Purchase of Split type Unit 2 tons / Cassette type/ Wall Mounted / Installation 5 Tons Carrier and Samsung, Hire manpower for Part Time jobs only Supervises junior HVAC technicians in the installation, split, mini-split and window units. Assign Other Manpower to other location of HVAC Installation VRV/VRF Daikin Unit Refrigerant R410A Leak testing check up and testing commissioning.--
Elec Mechanical Technician 03/2012 - 10/2012
Polystar General Services, Inc, Olongapo City, Zambales Philippines
Industry: Engineering and Maintenance
Character Reference Name: Mr. Raul Prado Occupation: Facilitator / Technical Head Company Address: #82 Bernabe street., Annex 16-18, better living Subd., Paranaque. Telephone No. 823-8833/ 776-0488/776-1838 Part Time Mobile No: 09159609019
ENGINEERING MAINT.HVAC/R- CHILLER PLANT OPERATION AYALA MALL HARBOR POINT SUBIC BAY FREEPORT.TRANE EARTHWISETM CENTRAVACTMWATER CHILLER WITH ADAPTIDE CONTROL LA CROSSE, WISCONSIN USA 410 TONNAGE CENTRIFUGAL TYPE COMPRESSOR & CHILLER DUN HAM-BUSH 310 TONNAGE SCREW TYPE VERTICAL COMPRESSOR MALAYSIA. Operate Trane Chiller 410 tonnage Model: CVHF410 w/d Refrigerant 123.4 units Alternate Operation. 2 units Everyday. Operate Dun Ham-Bush Chiller 310 tonnage Model: WCFX41SCS7ARK3R w/d Refrigerant 134a Screw type Compressor. Maintain dis charge line 120 (PSI) and suction line 41 (PSI). Temperature set point 44oF Operate Cooling tower Monitored motorized valve. Check Up Entering water and leaving water. Operate Cooling tower water pump stand by pressure 10 (PSIG) pressure in pounds per square inch, leaving water. Operate primary chilled water pump stand by pressure 80 (PSIG) pressure in pounds per square inch, leaving water. Operate Secondary chilled water pump stand by pressure 110(PSIG). pressure in pounds per square inch. Operate Trane 410 tonnage chiller Centrifugal Compressor 123 Refrigerant Centrifugal Mall Air-Conditioning Monitored status of Compressor condition. Ampere’s. Voltage reading running temperature status. Check up status of Chilled water supply. Entering Water must be 54 oF and leaving water 44oF.Monitored motorized valve. Monitored water flow sensor protection switch must be high flow. Monitored Oil tank temperature most be 145.0 oF. Monitored running hours 1000hrs must be replacement of oil. And check up for oil contamination. Monitored Evaporator entering water and leaving water of chiller With set Point 44oF Monitored Condenser entering water and leaving water flow 81.4 oF condenser approach must be 0.1psi Cooling tower maintain condition of water level, fan belt air flow Monitored Chilled water pump. Primary secondary pump, condenser pump. Back wash water. Distribute water chilled to Air Handling Unit 25 hp 8o tons to 10 hp to FCU fan Coil Unit 2 tons to AHU 5 tons. Monitor and check up mechanical motorized valve. Pressure gauge. temperature gauge. Balancing valve. Mechanical hydro test pressure for installation of FCU. AHU. PAU. Leak testing procedure and--
A/C-REF MECHANIC. SERVICE TECHNICIAN 01/2012 - 03/2012
KHENT AIRCONDITIONING REFRIGERATION SHOP CONCEPCION CARRIER,, Olongapo City, Zambales Philippines
Industry: A/C Shop and Spare Parts
Name: Diosdado Vitug. Occupation: Owner Company Address: NO. 1 Harris Street East Bajac- Bajac, OLONGAPO CITY Telephone No: (047)222-6428 Mobile No: 0949-414-9110 0929-453-3370
Public Residential and Commercial Industrial Private Service Repair and Maintenance. Part Time Trouble shooting and repair wall standing Air-conditioning 10 tons carrier unit at commercial building, Trouble shooting and repair split unit 2 tons Air-conditioning unit Preventive maintenance Air-conditioning Unit window type. Air curtain. Portable A/C Ceiling cassette. Ceiling Universal. Standing floor. Wall mounted Ceiling concealed. Fan Coil Unit. Split duct. Package type Unit Water Cooled Packaged Unit. Pump down and general cleaning of evaporator. Service job residential commercial and industrial refrigeration. Quotation. job estimation material cost labor cost. Scheduling technician for installation and other activities related to job priority and customer services.--
HVAC TECHNICIAN 11/2012 - 05/2017
THE VENETIAN COTAI HOTEL MANAGEMENT LTD, Macau, TAIPA MACAO Macau
Industry: HOSPITALITY
Character Reference Name: Mr. Seow Tin Hwee Occupation: Executive Director Facilities Company Address: ESTRADA DA BAIA DE NOSSA SENHORA DE ESPERANCA THE VENETIAN MACAO RESORT HOTEL EXECUTIVE OFFICE –L2 TAIPA MACAO Telephone No. 85328883862- 8118611
SHERATON HOTEL FACILITIES PREVENTATIVE MAINTENANCE TECH HVAC EXPERIENCE IN 4000 ROOMS. Preventive Maintenance of 2 tones Fan Coil Unit AIR Quality Energy Saving. Cleaning of Filter Screen Evaporator Coil Internal External Remove Odor and Black Mold and Condensation Line w/ Biocide. Check Up indoor fan coil unit for air leaks. air duck and airflow and air distribution system. Check Up and testing single phase motor high low medium speed and rotation. Check Up Evaporator Temperature Hot +32oc And Cold 18oc Check for free spinning Operation of the blower and fan Motors. Inspect the fan motor shafting for corrosion rusty. Spin the fan blade to check the bearing conditions and verify fan motor is freely spinning. Turn the unit On and immediately Off to check for proper spin up and listen for bearing noise and out of balance Vibration cause of noise operation. Clean and Treat the Condensate flow Path. VRV/ VRF Unit Installation. Trouble shooting repair Maintenance works. Cleaning the Condensate drain fan for sediment or scum build up and clean. All exposed pan surface. Condensation Drainage Pipe line. Preventive Maintenance of Fresh Air Unit 25 tons AHU.PAU. Change Filter Bag. Cleaning of filter screen. Installation of air ventilation pipe for CDP. Resolve the problems of condensation leak. Trouble shooting and repair and replacement part Mechanical valve. Electrical synchronous motor actuator Thermostat Control RCU control Unit. Change HVAC control circuit board. Energy Saver. Fan motor repair. BMS operation troubleshooting Repair AHU/ FCU / FAU/ Exhaust Unit. Deal with contractor to give other projects and permission to allow working in safety task . Updated latest job priority to supervisor and ECE Engineer. Help management to figure out other jobs issue cause of lack of Manpower like hotel kitchen Refrigeration other equipment regarding to HVAC/R Mechanical Plumbing , Planning and coordination’s Every day. Attend other meetings and discuss some of other issue. Schedule other works related to jobs priority. Monitor the manpower works in 8 hours on duty. Give other works to other colleague that not busy. Recycle the schedule of jobs to learn other colleague and for additional skills. Conducted training to other collogue to increase motivation for additional jobs skills . Assign manpower to other jobs responsibilities due to lack of manpower. Scheduling manpower to alternative annual leave and other benefits of company.--
H V A C/R CONTRACTOR 09/2011 - 01/2012
Self Employed, SM City Olongapo, Zambales Philippines
Industry: Contracting
Project Done: SM City Olongapo Status of Employment: (Self Employed) Part Time Globe Mobile No: +639174333364
HVAC REFRIGERATION 700 TONNAGE CENTRAVAC TRANE CENTRIFUGAL CHILLER TYPE COMPRESSOR REFRIGERANT 123.MALL PROJECT CONTRACTING WIRING AND TERMINATION. HVAC Instrumentation Electrical Control Panel Termination. Compressor lines to contactor interlock connection. Blower fan motor to contactor. Installation of Sigma Electronic Control Circuit. BMS program control Unit, Installation of Honeywell Control Circuit. Termination of control Panel of Air Handling Unit Wiring and termination of MCC1 Line Side to load side. MCC2 lines side to load side. Wiring and termination of primary and secondary pump 380 volts wye and delta connection. Installations of Control Thermostat to automatic Operation of Unit. Installations of Motorized Air dumper heaters. Installations of FCU Fan Coil Unit. Emergency Exhaust Unit. HVAC Design System Operation. Replacement Refrigerants. Lubricant Change-Over. Refrigerant Circuit Subsystem Maintenance. Electrical Subsystem Maintenance. Energy Saver. Preventative Maintenance service call. Refrigerant Circuit Subsystem Maintenance. MSDS Material Safety Data Sheet. Assign Manpower to Finish the Project. Commissioning.--
H V A C MECHANICS 10/2010 - 08/2011
AUJAN Industries Co,, Dubai Investment Part P.O Box: 116495, Dubai UAE, JABAL ALI United Arab Emirates
Industry: Bottling Company
Character Reference Name: Jahed A.M Hasan Occupation: Human Resources Manager Telephone No: +971 4885 3888 MOBILE NO: +971505905319
PLANT BOTTLING COMPANY MANUFACTURED RANI JUICE AND BARBICAN. PLANT OPERATION DISTRIC COOLING HVAC/R BITZER COMPRESSOR 700 TONNAGE AND AMMONIA 717 500 TONNAGE HVAC/REFRIGERATION ENGINEERING MAINTENANCE AND REPAIR, Maintenance and troubleshooting repair / Preventive maintenance technical inspection. Preventive maintenance of HVAC Unit. PETRA CARRIER, Based for Manufactured standard Procedure. HVAC Unit Low pressure to medium up to high. Triple Evacuation system. Recovery refrigerant charge base on EPA Mainstreams Engineering. Preventive maintenance of Air handling Unit. Heat exchanger Heating. Semi Hermetic Compressor Installation 30 tonnage Cold storage Freezer-10oC Operate 4 unit Chiller bitzer compressor Refrigerant 134. 2 unit everyday w/d 2 unit ammonia 717 refrigerant. Re pipe ping and preventive maintenance of Removing moisture, synthetic change oil. Preventive Maintenance of Bitzer 800 tonnage Compressor Screw Type for plant refrigeration and air conditioning, Charging 717(ammonia) for plant refrigeration air conditioning 44.0of Distribute chilled water supply for Air handling Unit and Fan coil Unit 6.6 Annual Maintenance. Periodical maintenance (Compressor. Motor. Overhauling) Condenser tube Cleaning Maintain maximum operating efficiency by removing foreign debris and scale.--
H V A C MECHANICS 12/2009 - 06/2010
DYNCORP International, Government Operation,, Log Cap IV May wand Afghanistan , Maywand Afghanistan
Industry: Army Contractor
Occupation: HVAC Supervisor Telephone No. 8172246434 My Mobile No: AFGHANISTAN: ROSHAN MOBILE NO: +93794385976
OPERATION ARMY CONTRACTOR ENGINEERING MAINTENANCE SERVICES IN HVAC/REFRIGERATION Maintenance and troubleshooting repair/ Preventive maintenance technical inspection. Environmental Control Units. Air tacs Units .F60 Unit. Alaska Unit. Federal Deployable Environmental Control Unit. EAS. Friedrich. Heat Pumps Unit. WILMS Flammable Gas Unit . Ice Machine, Recovery Charge Hydro fluorocarbon (HFC) R- 134A.Recovery Charge HYDROCLORO- fluorocarbons (HCFCs) R-22. Reefer Unit R-134A.Carrier Trans cold R-134A, Daikin THERMOKING R-134A, Recovery, Recycling, and Reclamation / Refrigerant Processing/ Recover and Destroy, Maintenance HVAC process documents, Monitoring and service repair of container van 20footer chiller and 40footer freezer emergency by pass control of electrical subsystem of freezer and chiller refrigerant type 134A for chiller 404A for Freezer and other is 502 refrigerant charge chiller and freezer brand thermo king.--
A/C Technician, Electrical Technician 09/2008 - 11/2009
Moulin D'OR Bakery @ Restaurant, ABEL Part Dubai Al KARAMA, Dubai United Arab Emirates
Industry: Restaurant ans Bakery
Character Reference Name: Mr. NIDAL GANTOS Occupation: Owner Telephone No. 04350150-065303036
AIRCONDITIONING/REFRIGERATION ELECTRICAL MAINTENANCE AND REPAIR, Check up and Trouble Shooting and repair A/C Unit, Fridge .Chiller, Electrical. Trouble Shooting and Repair Electric. MACADAMS Oven, Electric Ovens, Electric Heaters, Restaurant Equipment And Bakery Equipment, Centralized water chilled HCFC-22.Perform trouble shooting and repair of air handling Unit root top packages and chiller system. Diagnose control circuit diagram. Purchase Spare part for A/C Unit Electric oven. Repair Commercial Fridge Ice Machine. Dishwashing Machine. Compressor. Thermostat. Heating Element. Gas R22 R11 R404a R134a R12.--
HVAC TECHNICIAN 06/2006 - 12/2007
Kellogg Brown & Root Government Operation,, Log Cap III TIKRIT Iraq FOB SPEICHER, Tikrit Iraq
Industry: Army Contractor
Character Reference Name: Mr. Joseph Williams Occupation: HVAC Supervisor Telephone No. 713-970-5574/281-669-5520
ENGINEERING MAINTENANCE REPAIR LEADERSHIP SUPERVISION DIVISION OF HVAC AND REFRIGERATION Daily safety meeting tool box topic. Sign safety task instruction and activity hazard analysis, HVAC perform preventive maintenance, standard operating procedure, Trouble shooting and repair transit cold reefer van freezer and chiller. Proper recovery refrigerant. Recovery Charge Hydro fluorocarbon (HFC) R-134ARecovery Charge HYDROCHOLO- fluorocarbons (HCFCs) R-22 Trouble shooting and repair heating elements , overload relay thermostat, Trouble shooting and repair central/ split Chigo Unit / ACU / window carrier unit/ a/c heat unit/ water cold a/c, Installation of Ducting. Perform installation repair & maintenance of heating ventilation air conditioning & steam distribution equipment & system. Operate variety of equipment as needed to perform installs. Maintains and repair computerized electronic pneumatic device related to HVAC control. Blue print reading HVAC and Electrical Mechanical plan. Lay out and installation. Supervision Schedule Installation repair and service commissioning, Supervises maintenance & assign work orders routine. Prepare materials Requisition. Prepare daily man –hours Technician Work Order Resolve all work orders issues and maintenance schedule. Inspects tools of issued to the technician and evaluates the performance of the technician. Prepare Preventive maintenance Schedule & mayor activities. Commissioning of modified &additional building. Prepare (TI) Technical inspection of HVAC unit. Presentation spare parts for purchased and Materials Control Refrigerant recycle.--
Preventive Maintenance (A/C Units. Industrial Refrigeration) 03/2003 - 09/2003
Sam’s Development Resources Int’l,, Olongapo , # 91 FENDLER St. Eat TAPINAC. Philippines
Industry: Hotel and Restaurant
Reference Name: Mngr. Joseph CARINO Occupation: F n b Manager Sam’s Development, Telephone No. (63) (47)223-5455 / 222-3717 Fax No (63) (47) 222-3992 Length of Stay: 6 Month’s Part Time
Preventive maintenance a/c units, electrical wirings and other device, Troubleshooting repair refrigeration ice machine, water dispenser, Troubleshooting repair 4 door chiller 4 door freezer, Repair container van freezer and chiller, Preventive maintenance and troubleshooting repair and installation,--
Electrician (Electro Mechanical Industrial. HVAC and Refrigeration) 10/2003 - 05/2006
Subic Bay Marine Exploratorium,, OLONGAPO City , Zubic Philippines
Industry: Marine Mammals Entertainment
Character Reference Name: Ms, RUBI ONG BIERI Occupation: Director Telephone No. (63) (47)252-5880/9000
ENGINEERING MAINTENANCE DEPARTMENT DIVISION OF ELECTROMECHANICAL. PREVENTATIVE MAINTENANCE INDUSTRIAL REFRIGERATION MOTOR AND REPAIR. Electrical Trouble shooting repair 15 hp motor wye/ delta connection, trouble shooting of magnetic contactor w/ thermal over load relay, PCB board, electrical circuit, pan motor, timer, thermostat, sensor valve, electrical subsystem of package unit air conditioning refrigeration reefer van 40 footer 20 footer carrier Mitsubishi unit electrical by pas control to emergency. Mechanical Daily monitoring electrical mechanical checklist, Troubleshooting repair ice machine hot gas defrost water cold type. Trouble shooting repair a/c package type 15 toner to 20 toners, Troubleshooting repair window type split type whole mounted, Installation of semi hermetic compressor for freezer and chiller, Monthly cleaning preventive maintenance of all units. Monitoring and service maintenance trouble shooting and repair of Carrier Mitsubishi container van freezer 40 footer 20 footer chiller Refrigerant R12 and emergency by pass control of electrical subsystem. Replacement of 7.5 tonnage semi hermetic compressor installations. Monitoring and service repair of blast freezer tandem compressor refrigerant R22--
Industrial Electrician (Electro Mech. Industrial, HVAC-R) 08/2001 - 11/2002
AKASYA BPV INC,, Olongapo , Subic Philippines
Industry: Boiler Vessel Fabrications
Character Ref Engr. Godfrey S. baring Occupation: QA/QC Manager Telephone No. (082)235-2261 to 65/ (63-2)673-3645)
ENGINEERING MAINTENANCE DEPARTMENT DIVISION OF ELECTROMECHANICAL. PLANT BOILER VESSEL ENGINEERING ELECTRICAL MECHANICAL WORKS. Electrical Trouble shooting repair 3ph motor industrial control of package type a/c units, Trouble shooting repair electrical 3 phase magnetic contactor and over load, Trouble shooting repair over head crane15 toner and 10 toners, Trouble shooting repair y / delta connection motor control, Trouble shooting repair burn wirings of compressor, Mechanical Repair and installation of hermetic compressor 7.5 toner 3phase 91Lra, Repair and installation of semi hermetic compressor 7.5 toner 3phase,Charging HCFC-22.CFC12.HFC-134a and others, Preventive maintenance all industrial type of motor,--
Electrician (Electro Mechanical Indus, Ref, A/C Units, Heat Units) 06/1997 - 06/2001
ELECTRUCK PACIFIC, INC., Olongapo , Subic Philippines
Industry: Shift Repair Facilities
Character Reference Name: Mr. John R. Wellington Occupation: Work Manager Telephone No. (63) (47) 252 -6332-4/6 / (61) (2) 692 8844 Length Of Stay: 4 Year's Full Time
PLANT SHIP ENGINEERING MAINTENANCE REPAIR RIG DIVISION OF ELECTRICAL MECHANICAL. PREVENTATIVE MAINTENANCE ELECTRICAL MECHANICAL EQUIPMENT, Electrical Trouble shooting magnetic contactor forward and reverse. Electrical wirings of all industrial motor Compressor, Troubleshooting magnetic contactor normally open normally close contact, Electrical lay out and installations of all motor control. Installation and termination interlock connection. Trouble shooting and repair Mitsubishi reefer van container van freezer and chiller, Troubleshooting repair electrical problem of compressor or other industrial motor, Troubleshooting repair PCB board and other electrical device, Mechanical Installation of semi hermetic compressor and commissioning, Installation and repair crankshaft, bearings, pistons, piston rings valves, flapper valve. Trouble shooting repair mechanical problem of heat units, Installation of split type units and repair, Proper procedure and charge (CFC R-12) (HCFC R-22)(HFC-134a) Replacing expansion valve. Thermostatic expansion valve, Installation of 7.5 toner semi hermetic compressor, Cleaning of all a/c units and other ref and industrial motor, Maintenance all condition of industrial motor refrigeration a/c units and other equipment,--
Assistant Electrician/ A/C Technician 04/1994 - 01/1995
Establishment, Olongapo City, Zambales Philippines
Industry: Repair Shop
N/A
Assistant Electrician and A/C technician skilled worker to improved my knowledge and skill Experience installation and troubleshooting repair A/C Unit and saving money to continue my study in college.--

Education:

GUZMAN INSTITUTE OF TECHNOLOY 06/1995 - 03/1997
Manila, Quipo, United States
Degree: Associate's Degree
Major:INDUSTRIAL ELECTRICITY
Minor:N/A
Industrial electricity course: Core Topics: Fundamentals of Electricity: Understanding basic concepts like voltage, current, resistance, and Ohm's Law. Electrical Circuits: Learning about series, parallel, and combination circuits, as well as different types of common circuits. Electrical Safety: Adhering to safety procedures and regulations when working with electrical equipment and systems. Electrical Components: Identifying and understanding the function of various electrical components like motors, generators, transformers, relays, and switches.


Download Resume(Available to Employers Only):

Robert Aligue HVAC SPECIALIST



More About Roberto Tirona Aligue
Please sign in or sign up an employer to view Roberto Tirona Aligue's personal information.

  • Phone: xxx-xxx-xxxx
  • Email:xxx@xxxx.xxx
  • Visa: -
  • Work Authorization: -
  • Expected Salary: -
  • Intests & Hobbies: -