Looking For: Commissioning Engineer, Electrical Engineer
Occupation: Architecture and Engineering
Degree: Master's Degree
Career Level: Experienced
Languages: English, Urdu, Arabic
Highlights:
Skills:Testing, troubleshooting, maintenance, commissioning, relay calculation, design review, work procedure, report writing
Regional technical Support/commissioning & Maintenance 08/2016 - current
Saudi Electricity Company, Riyadh, Saudi Arabia
Industry: Utilities
• Testing Commissioning & Maintenance of (500kV, 380kV 132kV, 33kV, 13.8kV, 11kV Substations)
• Testing Commissioning & Maintenance of (Combined cycle and simple cycle Power plants, Solar PV Plants, Water
Pump Stations)
• Staff Health & Safety
• Development of testing Policy & Procedures, Troubleshooting’s, Root cause analysis.
• Technical bid clarifications, Technical Proposal reviews.
• HV & MV Design review
• Quality Improvement
• Cross-functional Team Collaboration
Component Testing: - CT testing using CT Analyzer (Verification of turn ratio, polarity, Resistance, accuracy class, excitation curve) & IR, VT testing (Verification of VT ratio, winding resistance) & IR, Circuit Breaker Testing (Timing, ductor, IR) MCB trip test, Pickup & timing test (trip, lockout, bi-stable latch & Auxiliary relays), Fuse Supervision Relays, Bus Bar (IR, ductor & High Pot), DS/ES (timing, ductor, IR), SF6 Gas Purification test, SF6 Gas Leakage test, SF6 Gauge Calibration,
Multifunction meters testing.
Primary Equipment Testing: Power Transformers, Auxiliary transformers, Generator step up Transformers, Motors,
Emergency Lube Oil systems, Turbine Inlet Air cooling systems, Ring Main Units.
Schematic, Function, Interlock Testing: -Transformer Control & Protection, Bus Bar Protection, Breaker Failure Protection, Generator & Motor control Protection, Bus Coupler & Bus Section Control & Protection Panel, Synch check Panel, Auto capacitor control system (ACCS), Auto Bus Transfer (ABTS), MV SWG C&P Panels, Under Frequency Protection, Under
Voltage Protection, Line Control & Protection Panel, ACDB, DCDB, Capacitor Bank Protection, Open Loop and Close Loop test for both SCADA and SAS base substations.
Protection Relays Configuration & Testing: Hand on experience on Generator protection, Motors Protection, Feeder Protection, Transformer Protection, Line Protection, Incomers, Bus Bar Protection (High & Low Impedance relays), Bus
Coupler & Bus Section Protection, Synch check Relays, Breaker Failure Protection, Load Shedding (UV, UF), Auto Recloser Relays, Capacitor Bank Protection,--